10

Max. number of units to be connected

The following tables show the maximum number of
units, which can be connected to the two outputs
(A1 or A2) on a CU 6005 Central Unit in total or to
each of the four outputs (A1, A2, B1 or B2) on a

CU 6010 Central Unit or to each output on an EX
6010 Extension Unit or to the output of a PS 6000
Power Supply.

CM/DM 60x0P Chairman/Delegate Units

Length of Feeding Cable

Type CAT5 AWG24

Length of inter connecting

Cable, Type CAT5 AWG24

Total cable length

Max. number of CM/DM

60x0 pr output

10 m

1 m

51 m

42

30 m

1 m

67 m

38

50 m

1 m

83 m

34

100 m

1 m

123 m

24

150 m

1 m

165 m

16

10 m

2 m

88 m

40

30 m

2 m

98 m

35

50 m

2 m

108 m

30

100 m

2 m

142 m

22

150 m

2 m

180 m

16

CM/DM 60x0P Chairman/Delegate Units & JB 6002 Junction Box

This configuration shows two CM/DM 60x0
Delegate/Chairman Units connected to one JB 6002
Junction Box with 3m cables between each JB

6002. Maximum 5 m cable from JB 6002 to
CM/DM 60x0 and max. one CM/DM 60x0 on each
output of JB 6002.

Length of Feeding Cable,

Type CAT5 AWG24

Length of Cable between each

JB 6002, Type CAT5 AWG24

Total cable

length

Number of

JB 6002

Max. number of

DM 60x0

10 m

3 m

61 m

18

36

30 m

3 m

75 m

16

32

50 m

3 m

89 m

14

28

100 m

3 m

127 m

10

20

150 m

3 m

168 m

7

14