Lighting instructions – millivolt gas valve – Lennox Hearth MLDVTCD-35NE User Manual

Page 20

Advertising
background image

20

LENNOX HEARTH PRODUCTS • MERIT

®

SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION

LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE

FOR YOUR SAFETY READ BEFORE LIGHTING

A. This appliance has a pilot which must be lighted with a piezo

igniter. When lighting the pilot, follow these instructions

exactly.

B. BEFORE LIGHTING smell all around the appliance area for gas.

Be sure to smell next to the floor because some gas is heavier

than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in your

building.

TO TURN OFF GAS TO APPLIANCE

1. Turn remote wall switch “OFF.” The pilot will remain lit for nor-

mal service.

2. For complete shutdown, turn remote wall switch to “OFF.”

3. Access the lower control compartment.

4. Depress gas control knob slightly and turn clockwise

to “OFF.” Do not force.

5. Close lower control compartment.

LIGHTING INSTRUCTIONS

6. Wait five (5) minutes to clear out any gas. Then smell for gas, includ-

ing near the floor. If you smell gas, STOP! Follow “B” in the safety

information above (to the left) on this label. If you don’t smell gas, go

to the next step.

7. Push in gas control knob slightly and turn counterclockwise

to “PILOT.”

8. Push in control knob all the way and hold in. Immediately light the

pilot by triggering the spark igniter (pushing the button) until pilot

lights. Continue to hold the control knob in for about 1-1/2 minutes

after the pilot is lit. Release knob and it will pop back up. Pilot should

remain lit. If it goes out, repeat steps 5 through 8.

If knob does not pop up when released, stop

and immediately call your service

technician or gas supplier.

If pilot will not stay lit after several

tries, turn the control knob to “OFF”

and call your service technician or

gas supplier.

9. Turn gas control knob counterclockwise

to “ON.”

10. Close lower control compartment.

11. If the appliance will not operate, follow the instructions "To Turn Off

Gas To Appliance" and call your service technician or gas supplier.

Immediately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob.

Never use tools. If the knob will not push in or turn by hand,

do not try to repair it, call a qualified service technician. Force

or attempted repair may result in a fire or an explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the

appliance and to replace any part of the control system and

any gas control which has been under water.

Note: Knob cannot be turned from “PILOT” to “OFF”

unless the knob is pushed in slightly. Do not force.

H I

LO

W

TPTH

TP

TH

PIL

OT

PI

LO

T

ON

i

t

OFF

OUT

IN

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY

RESULT CAUSING PROPERTY DAMAGE, PERSONAL INjURY OR LOSS OF LIFE.

1. STOP! Read the safety information above on this page.

2. Access the lower control compartment.

3. Turn remote wall switch to “OFF.”

4. Verify main line shut-off valve is open.

5. Push in gas control knob slightly and turn clockwise

to “OFF.”

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Advertising
This manual is related to the following products: