Troubleshooting the electronic ignition system – Lennox Hearth MLDVTCD-35NE User Manual

Page 26

Advertising
background image

26

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX HEARTH PRODUCTS • MERIT

®

SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION

TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM

SYMPTOM

POSSIBLE CAUSES

CORRECTIVE ACTION

Check voltage on AC terminals of module an/or batteries. The value should be

around 2.7 to 3.2 VAC. Confirm that wire connections are secure.

Check for visible cracked casing, cuts, etc.

Check pilot assembly for visibly broken spark electrode, etc.

Check voltage on D.C. terminal of batteries. The value should be around 3.0V

Ensure that the gas supply is turned on.

Ensure sensor wire connection is secure.

Ensure black, green and orange wires connection is secure to valve.

Ensure black sensor wire (S) and black igniter wire (I) is secure to ignition module.

Purge gas line of air.

Test voltage at AC terminals of module and/or batteries. It should be around

2.7 to 3.2 VAC.

Turned gas supply to "ON".

Check wire connection.

Check location of sensor.

Check vent system for obstructions.

Check for proper air shutter openings.

A. Low voltage/or bad lead

wires.

B. Damaged igniter wire.

C. Damaged pilot assembly.

D. Batteries Low

A. No fuel supply.

B. Loose sensor wire.

C. Lose wires to valve.

D. Loose wires to ignition

module.

E. Air in the gas line.

F. Low voltage.

A. Gas supply is turned

"OFF".

B. Loose wire connection on

valve or ignition module.

C. Flame does not engulf

flame sensor.

D. Obstructed vent system.

A. Improper air shutter

opening.

1. Nothing happens when

ON/OFF switch is turned

on (pilot does not spark).

2. The main burner does

not light and the igniter

is sparking.

3. The main burner come

"ON" but then go "OFF".

4. Glass soot.

Note: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall

switch are in the “ON” position.

Important: Valve system troubleshooting should only be accomplished by a qualified service technician.