Operation – Lincoln Electric Mobiflex 400-MS User Manual

Page 16

Advertising
background image

B-2

OPERATION

B-2

MOBIFLEX 400-MS

THE 400-MS FILTER CLEANING SYSTEM
(Continued)

The filter indicator will light during each automatic
cleaning pulse, or during the entire time a manual
cleaning cycle is running. If, after two pulses, the pres-
sure drop has not fallen below the set point, the indi-
cator will flash. This could be due to a saturated filter,
lack of compressed air, low air pressure or cleaning
equipment malfunction. If the filter is saturated,
replace the filter.

The alarm flash can be rest by pressing the
Reset/Start button next to the indicator.