TROUBLESHOOTING

D-2

MOBIFLEX 400-MS

Observe all Safety Guidelines detailed througout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

SYMPTOM

PROBLEM

SOLUTION

Filter Indicator Flashing

Note: To reset alarm, press
Clean/reset button next to the indica-
tor light.

Pressure relief valve opened on air
tank.

Filter Saturated

Cleaning System not working prop-
erly:

--Compressed air not connected

--Compressed air pressure too low

--Damaged valve or solenoid

--damaged PC board, or pressure
switch

Air Pressure too high

Replace Filter

Conect compressed air: 90 - 100 psi
clean & cry.

Connect 90 - 100 psi of clean, dry com-
pressed air

Replace valve-solenoid assembly

Replace PC Board or pressure switch

Regulate compressed air down to 90 -
100 psi.