Operation, Welding operation, Caution – Lincoln Electric WELDANPOWER 125 IM530-C User Manual

Page 21: Warning, Break-in period, Low oil sensing, Typical fuel consumption, General information

Advertising
background image

14

OPERATION

WELDANPOWER 125

Break-in Period

It is normal for any engine to use larger quantities of
oil until break-in is accomplished. Check the oil level
twice a day during the break-in period (about 50
running hours). Change the oil after the first 5 hours
of operation. See the Engine Instruction Manual for
further details.

IN ORDER TO ACCOMPLISH THIS BREAK-IN, THE
UNIT SHOULD BE SUBJECTED TO MODERATE
LOADS, WITHIN THE RATING OF THE MACHINE.
AVOID LONG IDLE RUNNING PERIODS. REMOVE
LOADS AND ALLOW ENGINE TO COOL SEVERAL
MINUTES AT LOW IDLE BEFORE SHUTDOWN.

-----------------------------------------------------------------------

Low Oil Sensing

This engine has a built in sensor which responds to
low oil level (not pressure). When activated, the
system will shut the engine down. The engine will not
restart until sufficient oil is added. Check oil level
frequently and add oil as required to the full mark on
the dipstick. DO NOT OVERFILL.

Typical Fuel Consumption

(For Codes 10158, 10160)

BRIGGS& STRATTON
9 H.P. VANGUARD

NO LOAD.

0.15 GALLONS/HOUR

2400 R.P.M

(.57 LITERS/HOUR)

NO LOAD

0.33 GALLONS/HOUR

3750 R.P.M.

(1.25 LITERS/HOUR

DC CC WELD OUTPUT

0.63 GALLONS/HOUR

100 AMPS, 25 VOLTS

(2.4 LITERS/HOUR

DC CC WELD OUTPUT

0.76 GALLONS/HOUR

125 AMPS, 25 VOLTS

(2.9 LITERS/HOUR)

AUXILIARY POWER

0.76 GALLONS/HOUR

4500 KVA

(2.9 LITERS/HOUR)

(For Codes 11183, 11406)

Robin / Subaru

9 H.P. EX 27

NO LOAD

0.31 GALLONS/HOUR

3750 R.P.M.

(1.17 LITERS/HOUR

DC CC WELD OUTPUT

0.66 GALLONS/HOUR

100 AMPS, 25 VOLTS

(2.48 LITERS/HOUR

DC CC WELD OUTPUT

0.70 GALLONS/HOUR

125 AMPS, 25 VOLTS

(2.66LITERS/HOUR)

AUXILIARY POWER

0.68 GALLONS/HOUR

4250 KVA

(2.59 LITERS/HOUR)

WELDING OPERATION

GENERAL INFORMATION

The Weldanpower 125 can deliver from 50 to 125
amps of welding output current . Output can be
adjusted by setting the current control dial on the
output control panel.

You can get maximum welding output by setting the
dial to 125 AMPS. At high current settings like this,
some output may decrease as the machine is used.
If you are welding for a long time, you may need to
turn the dial slightly upward to maintain the same
results.

The numbers on the dial correspond to the
approximate amps needed to weld using specific
Lincoln welding rods. Table B.2, WELDING
APPLICATIONS, or the electrode selection guide on
the machine output panel give you the recommended
dial settings based on the thickness of the work and
the size and type of rod you’re using.

TO USE THE WELDANPOWER 125 FOR WELDING:

1.

Remove the flange nuts from the weld output
terminals and place the work and electrode
welding cables over the terminals. See Figure
B.1 and B.1a. Replace and tighten the flange
nuts securely. Be sure the connections are tight.

CAUTION

ELECTRIC SHOCK can kill.

Do not touch electrically live parts

or electrode with skin or wet
clothing.

Insulate yourself from work and

ground.

Always wear dry insulating gloves.

WARNING

ENGINE EXHAUST can kill.

Use in open, well ventilated areas

or vent exhaust outside.

Do not stack anything on or near

the engine.

MOVING PARTS can injure.

Do not operate with doors open or

guards off.

Stop engine before servicing.

Keep away from moving parts.

Only qualified personnel should install, use, or
service this equipment.

Advertising