Mdw 9031 dual zone, Mdw 9031dcp dual zone – Lucent Technologies MDW 9031DCP User Manual

Page 14

Advertising
background image

MDW 9031/9031DCP Dual Zone Pocket Phone

503-801-169

Dual Zone Administration

Dual Zone Pocket Phone

1

Issue 2 April 1999

7

For MERLIN LEGEND in Key Mode, call coverage should be set up
between the two station ports so that both station ports ring
simultaneously on the Dual Zone handset.

For MERLIN LEGEND in PBX mode, each station port needs 2 shared
system access buttons for the other station port.

See your MERLIN LEGEND Communications System manual for
information on applying call coverage setups or for programming shared
system access buttons.

Note:

You must disable the Voice Announce feature for both station
ports (extensions) for the Dual Zone handset to work properly.

Administration for

DEFINITY

, Prior to Release 5.0,

and for System 25, System 75 and System 85

Refer to the appropriate section for either the MDW 9031 Dual Zone Pocket
Phone or the MDW 9031DCP Dual Zone Pocket Phone.

MDW 9031 Dual Zone

For DEFINITY Communications Systems prior to Release 5.0 and for
System 25, System 75 and System 85, you must administer 2 station ports (2
extensions)—one for each radio module. Each station port must be
administered with 3 call appearances of its own and 3 bridged appearances of
the other station extension number.

For station configuration settings, see the sample screens (Figure 1a and
Figure 1b) in Appendix A for Type 7303S.

MDW 9031DCP Dual Zone

For DEFINITY Communications Systems prior to Release 5.0, you must
administer 2 station ports (2 extensions)—one for each radio module. Each
station port must be administered with 3 call appearances of its own and 3
bridged appearances of the other station extension number.

For station configuration settings, see the sample screens ( Figure 3a) in
Appendix A for Type 8410D.

Advertising