Installation

(For Qualified Installers Only)

Travis Industries

4050418

1 0 0 - 0 1 1 5 6

Installation Example: Interior Vertical Installation

Type "L" Vent

6” Minimum

3”

Minimum

Floor Protection

2”

Minimum

9” Minimum

“Tee”

Outside

Air

(optional)

Floor Protection

24” Minimum

Insulation

must maintain

3” clearance.

Outside air may be drawn from

a ventilated crawl space.

2” Min.

3” Min.

Ceiling Support / Fire Stop Spacer

Roof Flashing

Storm Collar

Vertical Cap

Vent must

maintain 3”

clearance to

combustibles.

“L” Vent

Seal each vent
section (including
adapters, elbows,
etc...) by injecting a
liberal amount of
500° F. RTV
silicone into the gap
between sections.

500

° F. RTV

Silicone