Installation, Installation example: class a chimney retrofit, For qualified installers only) – Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove User Manual

Page 15: Travis industries

Advertising
background image

Installation

(For Qualified Installers Only)

1 5

Travis Industries

4050418

1 0 0 - 0 1 1 5 6

Installation Example: Class A Chimney Retrofit

Type "L" Vent

6” Minimum

3”

Minimum

Floor Protection

2”

Minimum

9” Minimum

“Tee”

Outside

Air

(optional)

Floor Protection

Outside air may be drawn from

a ventilated crawl space.

2” Min.

3” Min.

Class A Chimney Ceiling Support

Roof Flashing

“L” Vent to Class A Chimney Adapter

Class A Chimney

“L” Vent

Storm Collar

Class A Chimney must

maintain clearances outlined

in the chimney’s installation

instructions (usually 2”).

Seal each vent
section (including
adapters, elbows,
etc...) by injecting a
liberal amount of
500° F. RTV
silicone into the gap
between sections.

500

° F. RTV

Silicone