TABLE 3: HEAT INPUT LIMITS FOR DEMAND CRITICAL WELDS (cont’d)

Product Name

Diameters

Available (in)

High Heat Input

mm(in.) avg.

Low Heat Input

mm (in.) avg.

Exposure Time @

80°F / 80% Relative Humidity

Filler Metal with 70 ksi Minimum Tensile Strength Requirement per AWS

SuperArc

®

L-56

AWS ER70S-6

0.025

0.030

0.035

0.040

0.045

0.052

1/16

No heat input testing required

SuperArc

®

L-59

AWS ER70S-6

0.035

0.040

0.045

0.052

1/16

Lincolnweld

®

960/L-61

AWS F7A2-EM12K

1/8

65

32

Filler Metal with 80 ksi Minimum Tensile Strength Requirement per AWS

Excalibur

®

8018-C3

AWS 8018-C3 MR

3/32

1/8

5/32

3/16

7/32

1/4

No heat input testing required

UltraCore

®

81Ni1A75-H

AWS E81T1-Ni1M-H4

0.045

80

30

16 Weeks

0.052

78

30

1/16

74

30

UltraCore

®

81Ni1C-H

AWS E81T1-Ni1C-H4

0.045

74

31

16 Weeks

0.052

80

30

1/16

78

29

SuperArc

®

LA-75

AWS ER80S-Ni1

0.035

0.045

No heat input testing required

SuperArc

®

LA-90

AWS ER80S-D2, ER90S-D2

0.035

0.045

0.052

1/16

Pipeliner

®

70S-G

AWS ER70S-G

0.045

Pipeliner

®

80S-G

AWS ER80S-G

0.045

Pipeliner

®

80Ni1

AWS ER80S-G

0.040

0.047

Lincolnweld

®

960/LA-85

AWS F8A2-ENi5-G

1/8

65

32

Advertising