Background – Lincoln Electric D1.8 User Manual

Page 4

Advertising
background image

4

D1.8 Seismic Supplement Welding Manual

www.lincolnelectric.com

Background

In January 1994, the Northridge, California earthquake caused unexpected damage to a number of welded
steel-framed buildings in the greater Los Angeles area. The Federal Emergency Management Agency (FEMA)
funded a variety of investigations that sought to address both the immediate and long-term needs related to
solving the performance problems associated with welded steel moment-frame connections. Several
documents were published as a result of these investigations, including Recommended Specifications and
Quality Assurance Guidelines for Steel Moment-Frame Construction for Seismic Applications
(FEMA 353)

1

.

FEMA 353 discusses what has come to be known as the “Pre-Northridge Connection” and concluded that
“…the typical moment-resisting connection detail employed in steel moment-frame construction prior to
the 1994 Northridge earthquake… had a number of features that rendered it inherently susceptible to brittle
fracture. These included the following:





The most severe stresses occurred in the connection





“Wildcat” welding position





Connection detail makes it hard to inspect





Significant flexural stresses on the beam flange at the column face





Weld access hole geometry





High restraint





Weak panel zones

The report continued on to say “…additional conditions contributed significantly to the vulnerability of
connections...” including:





Low toughness FCAW-S welding the consumables





Low redundancy





Matching beam and column strength

FEMA 353 then proposed a variety of recommendations and quality assurance guidelines that addressed
various topics, including:





Overall structural design





Connection design





Connection details





Materials, including both base metal and weld metal





Workmanship





Inspection

Advertising