Interlock continuity test, A. primary interlock switch test, B. secondary interlock switch test – LG MV1825SW User Manual

Page 25: C. monitor switch test, Components test procedure results

Advertising
background image

7-14

A. PRIMARY INTERLOCK SWITCH TEST

When the door is opened slowly, an audible click
should be heard at the same time or successively
at intervals and the latches should activate the
switches with an audible click.
If the latches do not activate the switches when the
door is closed, the switches should be adjusted in
accordance with the adjustment procedure.
Disconnect the wire lead from the primary switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminal of the
switch. The meter should indicate an open circuit
in the door open condition.
When the door is closed, the meter should indicate
a closed circuit.
When the primary switch operation is abnormal,
make the necessary adjustment or replace the
switch with the same type of switch.

B. SECONDARY INTERLOCK SWITCH TEST

Disconnect the wire lead from the secondary
switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminals of the
switch. The meter should indicate an open circuit
in the door open condition. When the door is
closed, the meter should indicate a closed circuit.
When the secondary switch operation is abnormal,
make the necessary adjustment or replace the
switch only with the same type of switch.

C. MONITOR SWITCH TEST

Disconnect the wire lead from the monitor switch.
Connect the ohmmeter leads to the common
(COM) and normally closed (NC) terminals of the
switch. The meter should indicate a closed circuit
in the door open condition. When the door is
closed, the meter should indicate an open circuit.
When the monitor switch operation is abnormal,
replace with the same type of switch.
NOTE: After repairing the door or the interlock
system, it is necessary to do this continuity
test before operating the oven.

WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION

EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS.

TYPE NO. SZM-V16-FA-63 OR VP-533A-OF OR V-5230Q FOR PRIMARY SWITCH
TYPE NO. SZM-V16-FA-62 OR VP-532A-OF OR V-5220Q FOR MONITOR SWITCH
TYPE NO. SZM-V16-FA-63 OR VP-533A-OF OR V-5230Q FOR SECONDARY SWITCH

COMPONENTS

TEST PROCEDURE

RESULTS

SWITCHES

Check for continuity of the

Door

Door

(Wire leads removed)

switch with an Ohm-meter

open

closed

Primary
Switch

Monitor
Switch

Secondary
Switch

NOTE : After checking for the continuity of switches, make sure that they are

connected correctly.

NO

COM

NC

COM

NO

COM

INTERLOCK CONTINUITY TEST