LG MV1825SW User Manual

Page 31

Advertising
background image

7-20

NOTE: A MICROWAVE ENERGY LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS

SERVICED FOR ANY REASON.

(3) CHECKOUT PROCEDURES FOR CIRCUIT

BOARD

The following symptoms indicate a defective circuit
board.

1) The start function fails to operate but the high

voltage Systems, the interlock switches, the door
sensing and the relay check good.

2) The unit with a normal relay continuously operates.
3) Proper temperature measurement is not obtained.
4) The buzzer does not sound or continues to sound.
5) Some segments of one or more digits do not light

up, or they continue to light up, or segments light
when they should not.

6) Wrong figures appear.
7) The figures of all digits.
8) Some of the indicators do no flicker light up.
9) The clock does not keep time properly.