Operation – Lincoln Electric POWER FEED IM915 User Manual

Page 26

Advertising
background image

b-4

OPERATION

b-4

ITEM

DESCRIPTION

1

Status LED indicates system status.

2

Digital Meter Display is a bright LED display of key welding information. Adjusting Parameter
Knobs.

3

MSP4 Panel is used to set the weld mode, adjust the arc, change arc start/end parameters
and for set-up information.

4

Cold Feed - Gas Purge Switch, press the switch up to feed wire with weld output off. Press the
switch down for gas flow with weld output off.

5

2 step - 4 step Switch is used to choose between a 2 step trigger or a 4 step trigger operation.

6

Location for Optional Memory Panel. (Order K2360-1 for the memory panel. See Accessories
Section).

7

Cover for Optional Water Cooling Kit, remove when the water cooling kit is installed. See
instructions with water cooling Kit.

8

Trigger Connector 5-pin amphenol for connecting the MIG gun trigger. See Installation Section
for detail.

POWER FEED™ 10M SINGLE WIRE FEEDER

2

6

3

5

1

4

7

8

FRONT PANEL CONTROLS AND CONNECTIONS

CASE FRONT CONTROLS

FIGURE b.1

Advertising