Operation, B-25, Machine functionality by weld process – Lincoln Electric POWER FEED IM915 User Manual

Page 47

Advertising
background image

Material

Steel
Steel
Steel

PROCESS

GMAW, CV

GMAW, POWER MODE

FCAW, CV

WELD MODE

5

40

6

CV NON-SYNERGIC MODES

b-25

OPERATION

b-25

POWER FEED™ 10M SINGLE WIRE FEEDER

DESCRIPTION

Arc Force adjusts the short cir-
cuit current for a soft arc, or for
a forceful, digging arc.

ARC CONTROL

300

25.3

WFS AMPS

VOLTS TRIM

LESS
WFS

MORE
WFS

LESS
VOLTS

MORE
VOLTS

300

25.3

WFS AMPS

VOLTS TRIM

LESS
WFS

MORE
WFS

LESS
VOLTS

MORE
VOLTS

MACHINE FUNCTIONALITY bY WELD PROCESS

CV GMAW/FCAW (NON-SYNERGIC)
Use the following tables to review how the machine functions (output controls, arc control, Start options and weld
options) for the weld modes listed in the top table.

OUTPUT CONTROL KNObS, WELD MODE 5 & 6

200

2.0

WFS AMPS

VOLTS TRIM

LESS
WFS

MORE
WFS

SHORTER
ARC

LONGER
ARC

200

2.0

WFS AMPS

VOLTS TRIM

LESS
WFS

MORE
WFS

SHORTER
ARC

LONGER
ARC

OUTPUT CONTROL KNObS, WELD MODE 40

EFFECT / RANGE
(Soft)-10.0 to
(Crisp)+10.0

EFFECT / RANGE

Preflow Time
0 to 25.0 seconds

Run-In WFS:
Off, 30 to150 in/min.

Start Procedure
0 to 10 seconds

DESCRIPTION

Adjusts the time the gas flows
after the trigger is pulled and
prior to feeding.
Run-In sets the wire feed
speed from the time the trigger
is pulled until an arc is estab-
lished.
The Start Procedure controls the
WFS and Volts for a specified time
at the beginning of the weld.
During the start time, the machine
will ramp up or down from the
Start Procedure to the preset
Welding Procedure.

START OPTIONS
The start Options available in these Non-Synergic CV weld
modes, their adjustment range and function are as follows :

EFFECT / RANGE

Spot Timer:
0 to 120.0 Seconds

Postflow Time
0 to 25.0 seconds
Crater Procedure
(0 TO 10.0 SECONDS)

Burnback:
0 to .25 Seconds

DESCRIPTION

Adjusts the time welding will continue
even if tigger is still pulled. This option
has no effect in 4-Step Trigger Mode.
Adjusts the time that shielding gas
flows after the welding output turns off.
Crater Procedure controls the WFS
and Volts for a specified time at the
end of the weld after the trigger is
released. During the Crater time, the
machine will ramp up or down from the
Weld Procedure to the Crater
Procedure.
The burnback time is the amount of
time that the weld output continues
after the wire stops feeding. It prevents
the wire from sticking in the puddle and
prepares the end of the wire for the
next arc start.

END OPTIONS

START OPTIONS

END OPTIONS

SET

SETUP

IR PORT

STD CV MIG

WAVEFORM CONTROL TECHNOLOGY

5

WELD MODE

ARC CONTROL

START OPTIONS

END OPTIONS

SET

SETUP

IR PORT

STD CV MIG

WAVEFORM CONTROL TECHNOLOGY

5

WELD MODE

ARC CONTROL

Advertising