Troubleshooting, Caution – Lincoln Electric INVERTEC V160-S User Manual

Page 22

Advertising
background image

E-3

TROUBLESHOOTING

E-3

V160-S

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

Observe all Safety Guidelines detailed throughout this manual

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

Oxidation

Tungsten inclusions

Porosity

Hot cracking

1. lnsufficient gas.
2. No protection on the back side.

1. lncorrect electrode sharpening.
2. Electrode too small.
3. Operating failure (contact of the

tip with the workpiece).

1. Dirt on the edges.
2. Dirt on the filler material.
3. Excessive travel speed.
4. Current intensity too low.

1 Unsuitable filler material.
2. High heat supply.
3. Dirty materials.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.

PROBLEMS IN TIG WELDING

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Advertising