OUTPUT PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,

contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.

Call 1-888-935-3877.

CAUTION

The machine has high welding

output and no control

1. Potentiometer failure.
2. Control Board failure.

1. Replace Potentiometer.
2. Replace Control Board.

RED LED stays ON continuously 1. Shunt Cable damaged.

2. Control Board defective.

1. Check connection of white,

red and black leads on the

Inverter Board

2. Replace Shunt Cable

Assembly.

3. Replace Conrol Board.

Flashing YELLOW LED

1. Input Supply Voltage out of

tolerance.

1. Supply correct Input Voltage.
2. Check Control Board

conections.