Rs232c, System information, Fan control1 – Panasonic PT-D5600U User Manual

Page 36: Fan control2, Func1, Auto pow. off, Password, Auto pow.off, Option2 settings

Advertising
background image

36

OPTION2 settings

RS232C

This sets the communication parameters at the
serial terminals.
For details on the serial terminals, refer to “Using
the serial terminals” (pages 39).

IN BAUDRATE

: 9 600, 19 200 or 38 400 is

selected.

IN PARITY

: NONE, EVEN or ODD is

selected.

OUT BAUDRATE : 9 600, 19 200 or 38 400 is

selected.

OUT PARITY

: NONE, EVEN or ODD is

selected.

VPS SYSTEM

: MASTER or SLAVE is

selected.

GROUP

: A to Z is selected. MASTER

or SLAVE is also selected.

SYSTEM INFORMATION

The projector’s system information can be viewed.

SYSTEM INFORMATION

ROM VERSION

HIGH

LAMP1 TYPE
LAMP2 TYPE

LAMP2 ON

200h

TOTAL

300h

LAMP2 LOW

SET RUNTIME

300h

LAMP1 LOW

100h

200h
300h

100h

HIGH
TOTAL
LAMP1 ON

20
20

LAD55
LAD55

1. 00. 00

RETRN

FAN CONTROL1

The fan can be controlled in accordance with the
operating conditions.

NORMAL

: Standard setting

HIGHLAND : This is selected when using the

projector at an altitude of over
1 400 meters.

FAN CONTROL2

The fan can be controlled in accordance with the
direction in which the images are to be projected.

HORIZ.

: Standard setting

VERTICAL : This is selected when projecting

images at a significant angle toward
the vertical (more than 30 degrees
from the horizontal).

FUNC1

The user can set the function for the remote
control’s FUNC1 button.

LAMP POWER:

The button functions in the same way as
“LAMP POWER” of “OPTION2”.

ASPECT:

This button has the same functions as
“ASPECT” of “POSITION”.

SUB MEMORY LIST:

This button has the same functions as “SUB
MEMORY LIST” of “OPTION1.”

AUTO POW.OFF

The projector can be automatically set to the
standby mode if no signals are input for the set
duration.

DISABLE:

Standard setting. This function is set to OFF.

45MIN.–90MIN.:

The duration can be set in 15-minute
increments from 45 to 90 minutes.

PASSWORD

This function is used by a service person.
Input the password with the numeric buttons (0 to
9) of the remote control and press ENTER button to
confirm the entry.

• The auto power OFF function does not

work while the freeze function is used.

Note

H: HORIZ.
V: VERTICAL

3 0

°

3 0

°

3 0

°

3 0

°

V

V

H

H

• Select the correct FAN CONTROL2

setting in accordance with the direction
in which the images are to be projected.
Using the projector at the wrong FAN
CONTROL2 setting will shorten the
service life of the lamps.

Attention