Insert the power cord plug into the wall outlet and then
press the MAIN POWER switch.

Press the “ I ” button so that a picture is projected onto
the screen.

Press the “MENU” button to display the MAIN MENU
screen, and then press the

and

buttons to move

the cursor to select “OPTION2”.

Press the “ENTER” button to display the “OPTION2”
screen, and select “SYSTEM INFORMATION” with the
and buttons.

Press the “ENTER” button.

The SYSTEM INFORMATION screen will be displayed.

Press and hold the “ENTER” button on the projector or
the remote control for approximately 3 seconds.

An item “LAMP TIME RESET” will be added.

Select the lamp which has been replaced with the

and

buttons.

LAMP1: Replace the LAMP UNIT 1
LAMP2: Replace the LAMP UNIT 2

Press the ENTER button, and when the “LAMP TIME
RESET” display flashes, press the ENTER button again.

The used hours of the specified lamp unit will be reset to zero.
When more than one lamp has been replaced, repeat the procedure from
step .

• If the power does not turn on even after turning the MAIN

POWER switch “I”, turn the MAIN POWER “O”, confirm that
the lamp unit and door are installed correctly, and turn on
again.

Attention

MENU

PICTURE

ADVANCED MENU

OPTI0N2
TEST PATTERN

OPTION1

POSITION

LANGUAGE

LAMP TIME RESET

LAMP1

LAMP2
LAD55
LAD55L

LAD55

1433h

0h

1100h

0h

LAD55L

SYSTEM INFORMATION

ROM VERSION

HIGH

200h

TOTAL

300h

LAMP2 LOW

SET RUNTIME

300h

LAMP1 LOW

100h

100h

1. 00. 00

• When the “LAMP TIME RESET” display flashes, the lamp

time reset can be canceled by pressing the MENU button.

• The used hours of the lamp units can also be reset to zero

by taking the following action instead of steps

to

.

When lamp unit 1 has been replaced:

In the standby mode, press the number buttons in the

sequence of 737381, and then press the ENTER button.

When lamp unit 2 has been replaced:

In the standby mode, press the number buttons in the

sequence of 737382, and then press the ENTER button.

When the used hours have been reset, the lamp monitor

(LAMP1/LAMP2) will flash for 3 seconds.