Power on into test mode – Panasonic EB-GD30 User Manual

Page 39

Advertising
background image

TEST AND MEASUREMENT

MCUK991001C8

Section 6

Issue 1

Service Manual

– 33 –

Revision 0

6.3.1 External Testing Setup Procedure

IMPORTANT NOTE

To allow accurate measurement of the complete unit the test equipment must be connected as shown (Figure 6.6). The PCB
Test Setup must be used to enable repair to PCBs. Once repair/replacement is complete, the assembled unit must be tested
and calibrated with the jigs and tools connected as shown in Figure 6.7.

Full Test Equipment Requirements

For testing the handheld unit the following equipment is required:

1.

Interface box

2.

12 V power supply

3.

Personal computer (IBM compatible) with RS232 interface

4.

RS232 interface cable (9 pin straight through connection)

5.

GSM test station

6.

RF Adaptor

7.

Interface cable – JT00004

The channel box software (supplied on floppy disk) should be installed onto the main drive of the personal computer.

The RF cable is connected to the GSM test station via a suitable adapter. The 12 V supply is connected to the rear socket of
the Interface box.

Two modes are available for testing the handheld unit:

1.

Test Mode.

The Test Mode facility allows various sections of the handheld unit to be individually activated.

2.

Normal Mode.

The Normal Mode facility allows the handheld unit to be powered externally for call origination/receiving operations.

NOTE:

A suitable test SIM card will be required which is compatible with the GSM test station.

Power On into Test Mode

1.

Connect the test equipment into test mode configuration.

Figure 6.8: External test equipment setup

2.

Ensure that the following settings are made:

a. Interface box IFB003

Power:

UP position

IGN:

DOWN position

Mode

UP position

Voltage

Dependent upon operation:
5.6 V for PCB testing
4.8 V for Nickel Metal Hydride battery

b. Power supply

+12V DC:

OFF

Advertising