TEST AND MEASUREMENT

MCUK991001C8

Section 6

Issue 1

Service Manual

– 41 –

Revision 0

8.

Select PROGRAM TRIM PL MCH GSM.

Figure 6.18: Power level selection 2

9.

Highlight the PL14 field and press ENTER.

Figure 6.19: Power level selection 3

10. Enter the value calculated in step 6 into the data field and then press ENTER.

11. Press ESC.

12. At the GSM test unit re-measure the peak power.

13. Repeat steps 2 to 11 of this procedure for the remaining power levels, in the following order:

PL6, PL9 and PL19.

Power Levels between PL9 and PL6.

Power Levels between PL14 and PL9.

Power Levels between PL19 and PL14.

14. Calibrate PL5 (limits ±0.2dB).

15. After calibrating at channel 62, the carrier power must be measured and calibrated at LOW and HIGH channels as

described in steps 2 to 14.

16. Repeat steps 2 to 14 for the GSM 1800 settings in the following order:

PL10 (limits ±0.5dB).

PL1, PL5 and PL15.

Power levels between PL5 and PL1.

Power levels between PL10and PL5.

Advertising
This manual is related to the following products: