TEST AND MEASUREMENT

Issue 1

Section 6

MCUK991001C8

Revision 0

– 42 –

Service Manual

Power levels between PL15 and PL10.

Power level PL0 (limits ±0.2dB).

6.5.2 RSSI

This procedure describes the calibration of RSSI on the compensation channel (Mch = Ch 67). This process must be carried
out for LOW/BOTTOM CHANNEL and HIGH/TOP CHANNEL. The following channel settings are used in this procedure:

1.

Set up the test equipment as described in Section 6.3 and switch the unit into test mode as described.

2.

Apply a carrier frequency of +68KHz to the UUT (for Ch 67 = 948.400 MHz) at an input level of -90 dBm.

3.

At the Channel box highlight the CHANGE CH <67> field and press ENTER.

4.

Highlight the SET AGC 1 field and change the set value to 45 dB and press ENTER.

5.

Highlight the RSSI dBm <> field and press ENTER.

Figure 6.20: RSSI dB field

6.

If the measured value is not -90 ±1 then make the following calculation:
RSSI offset value = [-(90+MEASURED RSSI VALUE)] x 2

= [-90-MEASURED RSSI VALUE] x 2,

for example

[-(90+(-95))] x 2
= [-90-(-95)] x 2
= 10

Record the result.

Channel

GSM900

GSM1800

Low/Bottom

10

544

Mid

62

699

High/Top

105

885