Planet Technology DVR-460 User Manual

Page 64

Advertising
background image

DVR-460 User Guide

64

Please see the description below for each function:

Function Description

DETECT

Enable (ON) or disable (OFF) the function of “Motion Detection”.
If this function is enabled, you might need to set the motion detection sensitivity or
simply keep the default values. For details, please see the description below.

Motion Dete
Sensitivity

)

he

The

default value is 7.
SS
“Spatial Sensitivity”, is to set the sensitivity for detecting the size of one object (the

for

“Time of Sensitivity”, is to set the sensitivity regarding how long one object stays in the
detection area and triggers the recording. The smaller the value is, the higher
sensitivity for motion detection.
The highest sensitivity setting is 0, and the lowest sensitivity setting is 15. The default
setting is 2.

RE
“Reference”, is to set a reference for detection. The default value is 10, which means
the DVR will compare 10 continuous images at one time according to the sensitivity of
LS, SS, TS simultaneously.
The bigger the value is, the higher sensitivity for motion detection. The hi hest
sensitivity is 61.

ction

(LS / SS / TS / RE

Set the detection sensitivity in 4 different adjustable factors (LS / SS / TS / RE).
LS
“Level of Sensitivity”, is to set the sensitivity of comparing two different images. T
smaller the value is, the higher sensitivity for motion detection.
The highest sensitivity setting is 0, and the lowest sensitivity setting is 15.

number of the grids) on the screen. The smaller the value is, the higher sensitivity
motion detection.
The highest sensitivity setting is 0, and the lowest sensitivity setting is 15. The default
setting is 3.
TS

g

Alarm

Select N.C. (normal closed) / N.O. (normal opened) / OFF for the alarm polarity.
For N.C. / N.O. contact details, please refer to “APPENDIX 2”.

Motion Detection
Setting Area

Set the motion detection area by selecting the area grids with your mouse. Pink
grids represent the area that is not being detected while the transparent grids are
the area under detection. You can set multiple areas under detection.
Click “-” (Clear All) to set the whole area undetected.
Click “+” (Select All) to set the whole area under detection.

Apply / Return

To save the setting, click “Apply” and return to “Server Setting” window.
To discard the setting, click “Return” to directly return to “Server Setting” window
without saving.






Advertising