OPERATING YOUR HEATER

THERMOSTAT MODELS

n

FOR YOUR SAFETY

n

READ BEFORE LIGHTING

WARNING: If you do not

follow these instructions exactly, a

fire or explosion may result

causing property damage,personal

injury or loss of life.

A. When lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING smell all
around the appliance area for gas.
Be sure to smell next to the floor
because some gas is heavier than
air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

l

Do not try to light any

appliance.
l

Do not touch any electric

switch, do not use any phone

in your building.
l

Immediately call your gas

supplier from a neighbor’s
pho ne. Foll ow t he gas

supplier’s instructions.
l

If you cannot reach your gas

supplier, call the fire

department.
C. Use only your hand to push in
or turn the gas control knob.
Never use tools. If the knob will
not push in or turn by hand, don’t
try to repair it , call a qualified
service technician or gas supplier.
Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if
any part has been under water.
Immediately call a qualified service
t e c h n i c i a n t o i n s p e c t t h e
appliance and to replace any part of
the control system and any gas
control which has been under water.

n

LIGHTING

n

INSTRUCTIONS

1. STOP! Read the safety

information on the side of heater.

2. Make sure equipment shutoff
valve is fully open.
3. Turn control knob clockwise
to the OFF position.
4. Wait five(5) minutes to clear

out any gas. Then smell for gas,
including near the floor. If you
smell gas, STOP! Follow “B” in the
safety information on the side of
heater. If you don’t smell

gas, go to the next step.
5. Turn control knob counterclock-

wise

to the PILOT position.

Press in control knob for
five(5) seconds. (see Figure 20).

Note: You may be running

this heater for the first time
after hooking up to gas supply.
If so, the control knob may
need to be pressed in for 30
seconds. This will allow air to

bleed from the gas system.
l If control knob does not pop

up when released, contact a
qualified service person or

gas supplier for repairs.
6. With control knob pressed in,

push down and release ignitor
button. This will light pilot. The
pilot is attached to the front of
burner. If needed, keep pressing
ignitor button until pilot lights.

Note: If pilot does not stay lit, refer
to Troubleshooting, pages 14 through
16. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot with
match.To light pilot with match, see
Manual Lighting Procedure.
7. Keep control knob pressed

in for 30 seconds after lighting
pilot. After 30 seconds, release

control knob.
l

If control knob does not pop

up when released, contact

n

TO TURN OFF

n

GAS TO APPLIANCE

Shutting Off Heater
1. Turn control knob clockwise
to the OFF position.
2. Turn off all electric power to the
appliance if service is to
be performed.
Shutting Off Burner Only (pilot
stays lit )
Turn control knob clockwise

to

the PILOT position.

a qualified service person or gas
supplier for repairs.
Note: If pilot goes out, repeat

steps 3 through 7. This heater
has a safety interlock system.
Wait one(1)minute before lighting

pilot again.
8. Turn control knob counterclock-

wise

to desired heating level.

The main burner should light.
Set control knob to any heat
level between HI and LO.(see
Figure 20)

CAUTION: Do not try to ad-

just heating levels by using the
equipment shutoff valve.

Figure 22 - Burner Patterns

Figure 20 - Control Knob in The
OFF Position

Figure 21 - Pilot

Advertising