USING THE PST SYSTEM

BEFORE POWER ON

A Check List

It is very important that you check the following operational points:

Ventilation

This terminal must NOT be operated in an environment with

restricted ventilation. There must be at least 25 mm air clearance around any
top or side ventilation holes with a free flow of air around the unit at ALL
times for the installation.

Operating Environment

The equipment must not be operated or stored in extremes of both

temperature and humidity/moisture.

(Operating range 0

°

C to + 35

°

C and up to 80% relative humidity –

non condensing max. wet bulb 26

°

C)

Power Supply

The operating voltage of the power supply should be checked to

confirm that it is set within the range of the local power supply. The power
cable, the power outlet and any power fusing arrangements must conform to
local safety regulations.

UPS Battery (option)

General care:

The UPS battery is consumables beyond product warranty. Please

definitely observe the alerts in beginning of this manual. If the equipment is to
be powered off for more than few days, please always disconnect the battery
from the system. Reconnect it and turn on the system to recharge the battery
for 1 ~ 2 hours every 3 months for temperature lower than 30

°

C. Recharge for

1 ~ 2 hours every month for temperature over 30

°

C. Temperature above 40°C

must be strictly avoided as it could cause termination of battery life and
unexpected result even if the battery is not in work. The UPS battery can
support basically the data preservation and smooth running of the system
during intermittent or few minutes

(3 ~ 8 min. depending on loading and

battery condition) power failure if the power management option is installed.

Battery replacement:

In the preloaded OS for a PST7700 with power management option,

there is a built in utility Power Manager that will indicate the UPS battery

status of the battery. When an installed UPS battery is found to be disabled,
please replace the used up UPS battery at power off as soon as possible.

Emergency treatment:

The battery is constructed maintenance free and leakproof. Its storage