INTRODUCTION TO 4P CONNECTORS FOR THE AJ8 SWITCH
(produced by Nippon Tanshi co.,Ltd)

1. Switch mounting
Mount the switch with the hole cutting
dimensions shown in the dimensions.
Contact us if you are considering using a
panel of other than the recommended
size and shape.
2. Regarding fastening lead wires to
terminals
1) When connecting the tab terminals,
use a .250 Quick-connect and insert the
terminals straight in.
If they are skewed, the terminals will
require excessive insertion force.
In addition, there is some variation in the
insertion force required for different
receptacles from different manufacturers,
so confirm how much force is needed
under actual conditions.
Do not solder wires onto tab terminals.
2) With manual soldering: Complete the
soldering connection work within 3
seconds with the tip of the soldering iron
(60W soldering iron) at a temperature of
420

°C or lower, and take care not to

apply any force to the terminal area.

Avoid touching the switch with soldering
iron.

Refer to the diagram above, “soldering
position,” for details on the position where
a wire should be soldered to a terminal.
When soldering PC board terminals,
keep soldering time to within 5 s at 270

°C

soldering bath or within 3 s at 350

°C

soldering bath.
3) The terminals should be connected in
such a way that they are not under
constant stress from the connecting
wires.
4) Terminal material is copper alloy which
may discolor due to finger’s oil or after a
long time. But that discoloration does not
effect actual performance.

3. Resistance to chemicals
To clean the switch unit, use a neutral
detergent diluted with water.
Do not use acidic or alkaline solvents as
they may damage the switch.
Furthermore, be careful not to get any of
the detergent solution inside of the switch
while cleaning it.
4. Environment
Avoid using and storing these switches in
a location where they will be exposed to
corrosive gases, silicon, or high dust
levels, all of which can have an adverse
effect on the contacts.
5. Take care not to drop the product as
it may impair perfomance.

Contact terminal and ground terminal

Soldering position

When wrapping or soldering a wire
around a terminal, do so in the shaded
area indicated in the diagram at left.

1. Outline of UL1054 test
Overload test AJ8: 20A 250V AC
(Power factor 0.75 to 0.8)
50 operation
Endurance test AJ8: 16A 250V AC
(Power factor 0.75 to 0.8)
6

×10

3

operation

After testing, temperature rise of
terminals should be less than 30

°C and

no abnormality should be observed in
characteristics.

2. Outline of EN61058-1 test
After switching 5

× 10

3

times on the

above load condition at both 85

°C and

25

±10°C, temperature rise of terminals

should be less than 55

°C and no

abnormality should be observed in
characteristics.

+5

0

24A

50 to 100ms

J8: 16A

AC: 250V
(Power factor 0.6)

2 sec.

4 sec.

Notes) This AJ8 switch connector is not
available from Matsushita Electric Works.
Contact us for further details on this connector.

Connectors for
AJ8 switch

Suitable switches: AJ8 switch, .250 Quick-connect terminal
(Note: Terminal guard long type switches are not suitable for this connector.)

Housing
Product number: N1620-4204

Receptacle
Product number: 17168-2 (post-plated product for fine wires)

17168-M2 (material plated product for fine wires)
172131-M2 (for thick wires)

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.