F • Interworking Functions Information

Model 3086 G.SHDSL Integrated Access Device User Guide

186

Frame Relay Network Interworking (FRF.5)

FRN Rx Packets: 145/0

FRN Network Mgt: lmi_both

FRN Net Mgt State: port_mgt_UP

Channel Level Information:

---------------------------------------------------------------------

|Chn1 |DLCI|Net DLCI|Activate| Tx Pkt G/B | Rx Pkt G/B |Status

|chn1 |100 |0 |enable | 0/0 | 0/0 |active

|chn2 |101 |0 |disable | N/A | N/A |N/A

|chn3 |102 |0 |disable | N/A | N/A |N/A

|chn4 |103 |0 |disable | N/A | N/A |N/A

|chn5 |104 |0 |disable | N/A | N/A |N/A

|chn6 |105 |0 |disable | N/A | N/A |N/A

|chn7 |106 |0 |disable | N/A | N/A |N/A

|chn8 |107 |0 |disable | N/A | N/A |N/A

-------------------------------------------------------------------

Set configuration variables associated with the specified port
Command: frn set port# <variable> <value>

The “frn set port#” command allows the user to set port level specific variables to their optional values. All vari-
ables described above for the port level configurations are available from the “frn set port#” command screen.
The following example shows the setting of port #5 MuxMode to mux_many_to_one. NOTE that after the
first line the “?” was used to determine the possible configuration options available to the user.

Note

At any point during the typing of the command selecting the “?” will
display the possible options available to the user.

Note

After the first several letters of the command are typed pressing the Tab
key will tell the system to complete the variable or command name.

fi

frn set port5 MuxMode

mux_many_to_one

mux_one_to_one

fi

frn set port5 MuxMode mux_many_to_one

Configuration Management of the Channel Level Variables
The following information can be used to configure the Channel Level information associated with the FRN
connections. The CLI uses the “frn” directive of the CLI interface for Channel Level configuration. Note that
the “frn show port” and “frn list” commands already discussed at the port level are also useful to gain detailed
and overview information about the channels.

Understanding the Channel Level View
The Patton Electronics Model 3086 supports up to eight individual FRN Ports. Each port can support up to
eight Channels while set to the “many to one” multiplexing mode. To access the port level information the user