Parts and their functions – Panasonic AK-MSU930P User Manual

Page 13

Advertising
background image

13

Q Active switch [ACTIVE]

When this is pressed during the iris and the master
pedestal function priority display, the iris and the master
pedestal function priority changes, and the lamp of the
switch lights. When the ACTIVE switch on the ROP is
pressed, the iris priority is transferred to the ROP.

R Master pedestal level indicator

This indicates the master pedestal level.
Variable range: –99 to 99

S Master pedestal control [M-PED]

This is used to adjust the master pedestal level. The
control is a rotary encoder. The level is increased by
rotating the control clockwise.
Since the master pedestal adjustment is independent of
the R, G and B GAM adjustments, the R, G and B
pedestal adjustment values remain unchanged even
when the master pedestal control is rotated.

T Master pedestal storage switch [MEMO]

This is used to store the master pedestal rotary encoder
information in the memory.

U Master pedestal call file switch [RECALL]

This is used to call the master pedestal rotary encoder
information stored in the memory.

V DC power switch [POWER]

This sets the power of the main unit of the master setup
unit (AK-MSU930P) to ON or OFF.

W Circuit breaker

X CCU connectors [1 to 15]

These connectors are for signal interfacing with the
camera control unit (AK-HCU931P).

Y DC 12V input connector

[DC 12V IN] (XLR 4 pins)

The model AW-PS505 AC adapter (optional accessory) is
connected here.

Z Ground terminal [GND]

Parts and their functions

H Red tally, green tally indicator

Red tally indicator
This lights when the red tally signal is input to the tally
INCOM connector on the CCU.

Green tally indicator
This lights when the green tally signal is input to the tally
INCOM connector on the CCU.

I Auto iris switch [AUTO]

This is used to activate the auto iris function.
Lighted: The auto iris mode is established.
Off:

The lens iris is controlled by the iris control.

J Iris coarse switch [COARSE]

This is used to change the variable range of the iris in
respect of the displacement in the iris control.
When the iris active mode is transferred to ROP or RCP,
the switch setting is automatically released.
Lighted: The changes in the iris in respect of the

displacement in the iris control are increased.

Off:

The changes in the iris in respect of the
displacement in the iris control are reduced.

K Lens file storage switch [MEMO]

This is used to store the iris rotary encoder information in
the memory.

L Lens file call switch [RECALL]

This is used to call the iris rotary encoder information
stored in the memory.

M Lens shrinker display [a

a

0.8]

N Iris f-number indicator

This indicates the lens f-number.

O Lens extender display [LENS EXT]

This lights to warn that the setting of the lens extender is
other than 1a.
Lighted: The setting of the lens extender is other than

1a.

Off:

This indicates that the lens extender is not
being used or that the extender function is not
available.

P Iris control [IRIS]

This is used to adjust the iris level of the lens. The
control is a rotary encoder.
When the auto iris mode is not established:

The iris can be adjusted manually.

When the auto iris mode is established:

The iris level is adjusted automatically.

Advertising