Care and Replacement

28 -

E

NGLISH

Maintenance

Removing and replacing the lamp unit

J

Use a Phillips screwdriver to loosen the 3 lamp

1.

unit fixing screws until the screws turn freely.

Lamp unit lock

Lamp unit

fixing screws

Hold the handle of the lamp unit and release the

2.

lamp unit lock in the direction of an arrow.

Pull out the lamp unit gently from the projector.

3.

Replace the new lamp unit while making sure that

4.

the direction of insertion is correct.

Press the top of the lamp unit downwards and make

sure the unit is installed securely.

Press down here

Press down here

Tighten the lamp unit fixing screws securely with a

5.

Phillips screwdriver.

Attaching the top cover

J

Attach the hinge parts of the top cover to the

1.

projector and press slightly until it clicks.

When the projector is mounted on the ceiling,

attaching the hinge parts is not required.

Hook the top cover safety hook to the projector.

2.

Hook the tabs of the top cover to the front of the

3.

projector body and lower slowly.

Press the back corner of the top cover gently until

4.

it clicks.

Make sure to hook the top cover safety hook to the

body.

Top cover safety hook

Tabs

NOTE:

Be sure to install the lamp unit and the top cover of the projector securely. If they are not

securely installed, it may cause the protection circuit to operate so that the power cannot be

turned on.

Grip the handle and keep the lamp unit paralleled when you remove the lamp unit.

Do not switch the power on while the top cover is opened.

When the projector is mounted on the ceiling, keep the lamp unit paralleled up and remove.

Resetting the

J

LAMP RUNTIME

If the lamp usage time has passed 2 000 hours (when

LAMP POWER has been set to NORMAL), the

projector will switch to standby mode after approximately 10 minutes of operation. The resetting procedure

should thus be completed within 10 minutes.

Connect the power cord to the projector and a wall

1.

outlet, and switch

MAIN POWER on.

Switch the power button.

2.

Press the

3.

MENU button to display the menu.

Press ▲ ▼ to select

4.

OPTION and press the

ENTER button.

Press ▲ ▼ to select

5.

LAMP RUNTIME.

HIGH ALTITUDE MODE
LAMP POWER
VIERA LINK SETTINGS
TEST PATTERN

LAMP RUNTIME

OFF

NORMAL

1820H

Press and hold the

6.

ENTER button for

approximately 3 seconds.

The confirmation screen will be displayed and

7.

select

OK.

Switch off the power button to reset the duration of

8.

the

LAMP RUNTIME.

Confirm the duration of time in

9.

LAMP RUNTIME is

reset to “0”.