Operating Modes

Format :

WW

<CR>

7 fields integer <CR> (=YYMMDDWWHHMMSS<CR>)

Explanation :

The real time clock may be set using the following format:

YY

the last two digits of year

MM month

DD date

WW day, 00 means Monday, 06 means

Sunday

HH

hour 24-hour format

MM minute

SS second

NOTE: Input the 7-bytes integer as a single entry. If an integer is less than 7-
bytes in length, the player returns an error message.


Execution :

String

Status Return

DVD player

WW<CR> R<CR>

Set Real Time Clock setting
mode

06051500123456<CR> R<CR>

Sets Monday, May 15t,
12:34:56, 2006


6.18 Advanced

Setup

Function

: current setting of Advanced Setup Menu is rewritten

Format :

Integer

MS

Explanation : The command rewrites the Advanced Setup Menu settings,

which is expressed as an integer. The integer value is made up of the sum of
the selected arguments. The player returns an error code if the command is
issued while the Advanced Setup Menu is on the screen. The factory default
value is 0.


The Advanced Setup Request command (?S) reveals the current setting.

Description

Argument Function

0 1

1 WEEKLY

TIMER

OFF

ON

2

POWER ON START

OFF

ON

4

TITLE PLAY MODE

SINGLE

ALL

8

16

REPEAT MODE

(0) OFF, (8) CHAPTER

(16) TITLE, (24) DISC *1)