Construction and installation, Opening the kws1500 – Polycom KIRK KWS1500 User Manual

Page 32

Advertising
background image

KIRK Wireless Server 1500 Installation and Maintenance

5.2 Construction and Installation

The KWS1500 should be installed on a desk, or wall-mounted using the included wall-
mounting bracket. When installing the KWS1500, maintain a clearance of four inches
around the chassis to provide adequate ventilation. For this reason, do not place any
objects directly against the panels.

The KWS1500 requires a mounting area at least 18” x 15” plus additional space for
installation of cross-connection blocks.

A dedicated power source is highly recommended; it should be located within 1.8 meters
/ 6 feet of the installation.

5.3 Opening the KWS1500

Do not remove the top cover while the unit is connected to a power source.
Failure to disconnect the unit from the power source while the top cover is
removed can cause severe electric shock, damage to electrical components,
and even death.

Remove the eight screws connecting the cover to the chassis. There are two screws on
each side of the chassis, and four located on the rear of the chassis. Once the screws are
removed, gently lift the cover from the chassis and set it aside in a safe location.

Installation is the reverse of removal.

72160400_issue_B

32

Advertising