Wiring base stations, 6 wiring base stations – Polycom KIRK KWS1500 User Manual

Page 36

Advertising
background image

KIRK Wireless Server 1500 Installation and Maintenance

Analog interface card cable wiring

5.6 Wiring Base Stations

KIRK Base Stations are connected to the KWS1500 using a RS-232C 25-pin male cable
connected to the RS-232C 25-pin female connector located on the rear of the KWS1500.

Terminate the Base Station cable to a suitable connection point such as a punch-down
block or patch panel.

All Base Stations should be cabled using 24-gauge, Cat 5, twisted-pair cable. Terminate
the Base Station end of the twisted-pair cable with an RJ-11 connector on the center pair.
Base Stations are not polarity sensitive.

Terminate the solution end of the twisted-pair cable to a suitable connection point such
as a punch-down block or patch panel located close to the termination of the Base Station
cable. Cross-connect the Base Station cables to the desired Base Station circuit.

Power for the Base Station is provided by the KWS1500 and is delivered via the cable to
the Base Station.

After the physical connection is made, the LED in the center of the Base Station will flash.
This indicates that the Base Station is receiving power from the KWS1500.

Once the Base Station synchronizes with the KWS1500, the LED will light steady.