PARTS LIST

(MOTOR FAN ASSEMBLY)

1

2
3

4

5

7

6

8

9

EXPLODED VIEW

(MOTOR FAN ASSEMBLY)

Ref. No.

Part Name & Description

Part No.

Quantity

Remarks

1

Fan Case

AMC53F-AVØØU

1

2

Nut

AMC33F-ACØØU

1

3

Washer

AMC62F-AVØØU

1

4

Fan

AC98FRFZØØ

1

5

Washer

AC62FRFZØØ

1

6

Spacer

AC6ØFRFZØØ

1

7

Brush Assembly

AC27FRFZØØ

1(Set)

8

Bracket

ACØ2DV3ZØU

2

9

Screws

AC4ØDV3ØØU

4

NOZZLE HOUSING AND SHORT HOSE REPLACEMENT

Removal

1. Remove the lower plate as outlined in the LOWER
PLATE REMOVAL/INSTALLATION section.

2. Remove the belt and agitator assembly as outlined in
the respective sections.

3. Remove the nozzle hose by pulling it up out of the
nozzle housing and then pulling it, while twisting, out of
the wand holder.

4. Insert a flat blade screwdriver between the nozzle
housing and the plastic shaft, pry out the plastic shaft as
illustrated, (Fig. 10).

5. Remove the nozzle housing as illustrated, (Fig 11).

6. Remove the handle release assembly as outlined in its removal
section.

7. Remove the light cover, (Fig. 12) by removing the two (2) screws from
the nozzle housing and pushing out on the cover (Fig. 12).

8. Remove window, furniture guard and slider support.

NOTE: If the motor case cover is removed, DO NOT turn vacuum
over as the motor may fall out.

Installation

1. Install the light cover, handle release assembly, furniture guard,
window and slider support in the new nozzle housing. (Fig. 12).

2. Fit the nozzle from the motor shaft side first and rotate it into
place on the dust container as illustrated, (Fig. 13).

3. Slide the plastic shaft through the nozzle housing and into
the dust container. Make sure that the slot on the bottom of
the plastic shaft is down and fitted onto the projection.

4. Reassemble the nozzle hose by inserting it into the wand holder
then place the other end into the nozzle housing with the tab fitting into the slot.

5. Install the belt, agitator assembly, and the lower plate according to the respective instructions.