Polycom EF2241 User Manual

Page 14

Advertising
background image

I

NSTALLATION

V

ORTEX

EF2241

Reference Manual

12

Technical Support: 800.932.2774

whichever preset you want to come up after power up). The unit will need to be con-
figured for your system.

P

ROGRAM

P

ARAMETERS

F

ACTORY

D

EFAULT

P

RESET

V

ALUE

S

YSTEM

P

ARAMETERS

Preset

0

Device ID

0

A

UTOMIX

P

ARAMETERS

Chairman Mode

Off

Decay Time

1000 ms

Hold Time

500 ms

Last Mic On Mode

On (on Automixer 1)

Max NOM per Automixer

4

Off Attenuation

-15 dB

I

NPUT

C

HANNELS

Acoustic Echo Cancellation

On

Automatic Gain Control (AGC)

On

AGC Rate

1 dB/s

AGC Max Gain

3 dB

AGC Min Gain

-3 dB

Automixer

1

Echo Canceller Reference

Ref1

Filtering

Off

Gate Priority

1

Adaptive Threshold

10 dB

Gate Threshold

Adaptive

Gating

Auto

Advertising