Ef b, Onnecting, Nbalanced – Polycom EF2241 User Manual

Page 57: Alanced, Hoenix, Aking, Erminator

Advertising
background image

C

ONNECTOR

P

INOUTS

© Polycom, Inc.

53

V

ORTEX

EF2241

Reference Manual

C

ONNECTING

U

NBALANCED

RCA

TO

B

ALANCED

M

INI

P

HOENIX

1. Connect RCA Tip to Phoenix pin 1.
2. Connect RCA Ring to Phoenix pin 2.
3. Connect Phoenix pin 3 to Shield, and leave Shield floating on RCA end.

M

AKING

AN

EF B

US

T

ERMINATOR

Instructions

To make a terminator (for use when connecting EF2280s), use an RJ45 connector.
Connect pin 3 to pin 6 with an 110 Ohm resistor. A terminator is not required for the
EF2241 as it is built in.

Figure 31. Cable construction for connecting unbalanced RCA to balanced mini Phoenix (3 conductor terminal
block).

Red

Black

Red

Black

Shield

Tip

Ring

RCA Male

Mini (3.5 mm) Phoenix

2

1

3

+

-

Caution!

Do NOT connect the shield at both ends.

Caution!

On the EF2241, Phoenix pin 3 is connected to
chassis ground. Under no circumstances should

Phoenix pin 3 be connected to pin 1 or to pin 2.

Doing so will add noise to the audio signal.

Figure 32. The terminator

1 2 3 4 5 6 7 8

110

Advertising