Lcd m, Global settings, Automixer – Polycom EF2241 User Manual

Page 34: Ef2241, And g

Advertising
background image

LCD M

ENU

S

TRUCTURE

V

ORTEX

EF2241

Reference Manual

32

Technical Support: 800.932.2774

T

HRESHOLD

, M

ANUAL

T

HRESHOLD

, and G

ATE

P

RIORITY

.

Global Settings.

Decay Time. Decay time is the amount of time the microphone audio takes to
ramp down to the Off Attenuation level after Hold Time. Decay Time values
range from 0 to 5000 msec. The default value is 1000 msec.
Hold Time. This is the amount of time the microphone stays On after the energy
in the channel drops below the gating threshold. The default value is 500 msec.
The range is 1 to 5000 msec. Microphone channels gating On and Off too fre-
quently during short pauses in speech might be the result of setting the Hold
Time too low while too many microphones gating on at the same time may be the
result of Hold Time values that are too high.
Camera Gating Threshold. Specifies the hold time for camera gating informa-
tion.

Figure 22. Automixer parameters.

Ambient Level

A

DAPTIVE

T

HRESHOLD

Channel OFF

Channel ON

Channel turns on when

signal level is above

Adaptive Threshold

Microphone

Audio

Time

Signal Level

H

OLD

T

IME

O

FF

A

TTENUATION

D

ECAY

T

IME

Global Settings

Decay

Hold Time

Camera Gating

Threshold

Automixer

Advertising