Verifying operation and testing connections, To connect the sdcp to a dsu – Paradyne COMSPHERE 3615 User Manual

Page 43

Advertising
background image

Installing the Model 3616 DualFlow DSU

3-11

3615-A2-GB20-20

December 1996

Verifying Operation and
Testing Connections

Perform verification testing after any installation.

After installing and configuring the circuit (including

control and tributary DSUs, the DDS network, the DBMs
and their dial connections), perform a series of tests from
the control DSU
to verify network operation (using either
the SDCP or NMS).

To Connect the SDCP to a DSU

For the carrier-mounted Model 3616 DSU, the SDCP

must first be reconnected to the DSU. Once connected, the
SDCP operates like a DCP.

.

Procedure

1. Press the Select key (refer to Figure 3-2).

A screen similar to the following appears.

F1

F2

F3

Carr:Slot: 1: 01 A

1:0 2 A

The cursor is usually positioned under the second
position of the slot number (1:0 1 ).

In this example, the first line shows

1 indicates Carrier 1 (Carr)

01 indicates the DSU in Slot 1

A is reserved for future use

On the second line

Press the F1 key (

) to increment the number

that the cursor is on.

Press the F2 key (

) to decrement the number.

Press the

and

keys to move the cursor

one position to the left or right, to change either
the carrier or slot number.

Press the F3 key to toggle between DSUs, to
switch from 1:01A to 1:02A in this example.
(In our example, the previously accessed DSU
was located in Slot 2 of Carrier 1.)

2. Press the Select key on the SDCP again.

The SDCP accesses the DSU in Carrier 1, Slot 1.
The top-level menu (your starting point) of the
carrier-mounted DSU is displayed.

F1

1: 01 A DSU 9.6 C
Local Remot

F2

F3

From the first line of this example, you can see
that this is a carrier-mounted DSU (1:01A instead
of Port1) that is located in Carrier 1, Slot 1, is
operating as a DSU (i.e., not as a DBM), at
9.6 kbps, and is configured as a control (C).

From the second line you can see that there are no
NMS messages (no Msg branch over the F3 key)
waiting to be read and cleared.

Also note that the SDCP indicator on the selected
DSU’s faceplate, Front Panel, is lit.