COMSPHERE DualFlow Data Service Units

5-8

December 1996

3615-A2-GB20-20

Table 5-2

(2 of 3)

DSU Port Configuration Options

LSD Lead: Std
Next Std Delay FrcOn Prev

Line Signal Detect Lead. Controls behavior of the Line Signal Detect lead.

Std

LSD lead goes Off in response to a control mode idle (CMI) signal from the DDS network or DDS failure.

Delay

LSD does not go Off in response to a network alarm condition or CMI. LSD goes Off only after a
successful backup connection is established.

FrcOn

Keeps LSD on as long as the DSU has power.

DSR FrcOn: Enab
Next Enab Disab Prev

Data Set Ready Forced On. Provides the ability to override any other options controlling the Data Set Ready lead.

Enab

DSR remains ON as long as the device is working, regardless of tests and network alarms.

Disab

DSR functions as an active lead reflecting various test and alarm conditions and other options.

SystemStat: Enab
Next Enab Disab Prev

System Status. Controls the behavior of the DSR lead in response to a No Signal, Out-of-Service, or Out-of-Frame alarm
from the network.

Enab

Network alarm turns Off DSR.

Disab

Network alarm does not affect DSR.

DSR on Tst: Enab
Next Enab Disab Prev

Data Set Ready On in Test. Controls the behavior of the DSR lead during testing.

Enab

DSR is ON continuously during testing, allowing a DTE that relies on DSR being ON to send test
messages to the DSU.

Disab

DSR is Off during testing.

Circ Assur:Disab
Next Enab Disab Prev

Circuit Assurance. Controls behavior of the CTS lead in response to a data signal from the network. If CTS Cntrl is set to
RTS and RTS Cntrl is set to FrcOn, this configuration option is ignored.

A DDS Facility Alarm condition turns Off the CTS lead, regardless of the Circuit Assurance setting.

Enab

The DSU will turn Off the CTS lead if the DSU receives control mode idle (CMI) from the network.

Disab

The DSU is not affected by the receipt of CMI.

RespondRDL:Disab
Next Enab Disab Prev

Respond to Remote Digital Loopback. Determines whether the DSU responds to a V.54 Remote Loopback request.

Enab

Performs a Digital Loopback.

Disab

Ignores the Loopback command.