Paradyne COMSPHERE 3615 User Manual

Page 75

Advertising
background image

COMSPHERE DualFlow Data Service Units

5-10

December 1996

3615-A2-GB20-20

Table 5-3

(2 of 4)

DBM Configuration Options

TxClkSource: Int for a control DBM, RXC for a tributary DBM
Next Int RXC Ext Prev

Transmit Clock Source. Source of timing for the DBM. Only appears for a V.32 DBM.

Int

Internal clock source. The local DBM provides the timing. This source is used primarily in point-to-point
applications.

RXC

Receive clock source. This source is used primarily in multipoint tributary applications.

Ext

External clock source. This source is used primarily in applications where the connected DTE must
provide the timing, such as when a 3616 V.32 DBM with its DBM

Primary Core configuration option set to

Yes and where timing is received from the digital bridge.

CarrLossDisc: Yes
Next Yes No Prev

Carrier Loss Disconnect. Controls whether the V.32 DBM terminates a call when the receive signal carrier is lost or the
signal becomes unacceptable.

Yes

Call is terminated upon loss of carrier.

No

For factory testing only. Never set Carrier Loss Disconnect to No. Doing so will cause an off-hook line
condition, resulting in excessive telephone charges.

Auto Retrain:Yes
Next Yes No Prev

Automatic Retrain. Controls the automatic start of a retrain sequence by the DBM when received signal quality becomes
unacceptable.

Only appears for a V.32 DBM.

Yes

Retraining is initiated automatically.

No

Retraining is not initiated automatically; however, the DBM will respond to a retrain request from a remote
modem.

Single Rate: No
Next Yes No Prev

Single Rate. Determines whether the DBM will adjust its rate to resolve a rate mismatch with a remote DBM. Single Rate
must be set to Yes if rate adaption or non-disruptive diagnostics are enabled.

Only appears for a V.32 DBM.

If Rate(Kbps) is set to 2.4, the DBM can only talk to a 2.4 kbps modem, regardless of the Single Rate setting. (Will only
train at 2.4 kbps.)

Yes

The DBM operates only at the rate for which it is configured.

No

The DBM will adjust its rate downward to correct a mismatch.

AutoAnswer: Enab
Next Enab Disab Prev

Automatic Answer. Controls whether the DBM answers incoming calls.

Enab

DBM answers incoming calls.

Disab

DBM does not answer incoming calls.

Advertising