Dsu technical specifications – Paradyne COMSPHERE 3615 User Manual

Page 17

Advertising
background image

About Your DualFlow DSU

1-5

3615-A2-GB20-20

December 1996

Table 1-2

DSU Technical Specifications

Specifications

Criteria

APPLICATION

Full- or half-duplex data transmission via point-to-point DDS network, or
local area data channel

COMMUNICATION LINE

Leased or private 4-wire DDS line

DATA RATES

Digital Services (DDS, ASDS)

LADS

When timing is external (provided by the
DTE), the DTE’s clock must be within these
ranges.

2.4, 4.8, 9.6, 19.2, 38.4, 56, and 64CC kbps

2.4, 4.8, 9.6, 19.2, 38.4, 56, and 64 kbps

64 kbps

"

11 bps

56 kbps

"

9 bps

38.4 kbps

"

4 bps

19.2 kbps

"

5 bps

9.6 kbps

"

1 bps

4.8 kbps

"

0 bps

2.4 kbps

"

0 bps

DDS NETWORK INTERFACE

3615 DualFlow DSU

3616 DualFlow DSU

8-pin modular jack, USOC RJ48S

(One or two) 50-pin connector, USOC RJ48T

DIAGNOSTIC INTERFACE

3615 DualFlow DSU

3616 DualFlow DSU

Requires 3600 Hubbing Device which provides two 8-pin modular jacks

Via the SDU in the COMSPHERE

r

3000 Series Carrier

NETWORK COMPATIBILITY

ANSI T1.410 – 1992 and
AT&T Technical Reference 62310 – 1987

Integrated Network Corporation
Compatibility Bulletin CB-INC-101, and
Pacific Bell publications
PUB L-780035-PB/NB and
PUB L-780036-PB/NB

2.4, 4.8, 9.6, 56, and 64CC kbps

19.2 kbps loop at levels of + 6, 0, or –10 dBm

DSU COMPATIBILITY

Primary Channel

All Paradyne digital products and other products that are compliant with
AT&T Technical Reference 62310 – 1987