Connecting to the NMS

A 3600 Hubbing Device is required to connect the

control DSU to the 6700 or 6800 Series NMS. When
connected to the NMS, the DSU can be controlled and
configured from the NMS rather than from the DCP
alone.

.

Procedure

1. Plug the 4-pin modular plug of the 3600 Hubbing

Device (Figure 2-3) into the DSU jack labeled
CC/DC.

2. Plug one end of an M6BJ cable into the hubbing

device jack labeled CC IN/DC OUT.

3. Plug the other end of the 6-pin M6BJ cable into

the 6-pin end of the 873A adapter.

4. Plug the D-type end of the 873A adapter into the

appropriate 6700 or 6800 Series NMS jack.

Refer to your COMSPHERE 6700 or 6800 Series NMS

documentation to control and configure the DSU from the
NMS.

496-14576a

NMS NETWORK

CONNECTION

CC/DC

HUBBING

DEVICE

LOW VOLTAGE

AC POWER IN

TO

NMS (873A)

3000HUBBING DEVICE

MODEL

#3000-F3-300

Figure 2-3. Model 3615 DSU

NMS Connection

Connecting to the Dial (or PSTN) Network

If your DSU is equipped with a V.32 DBM, refer to

Figure 2-4 as you follow these steps.

.

Procedure

1. Plug either end of the dial (analog) interface cable

into the DSU jack labeled BACKUP.

Permissive service – telephone cord with 6-pin
modular RJ11C plug

Programmable service – telephone cord with
8-pin RJ45S plug

2. Plug the other end of the cable into the modular

jack provided by the telephone company, USOC
RJ11C (permissive) or USOC RJ45S
(programmable).

3. If your site has programmable service, verify that

the DSU’s hardware strap S1-1 is switched to the
OFF position.

Figure 2-4. Model 3615 DSU

Dial (PSTN) Network Connection