Paradyne COMSPHERE 3615 User Manual

Page 32

Advertising
background image

COMSPHERE DualFlow Data Service Units

2-12

December 1996

3615-A2-GB20-20

Verifying the Network

Perform a Health and Status check on the DDS circuit

to ensure that the network is functioning.

.

Procedure

1. Select Local (F1).

2. Select Stat (F1).

3. Select H/S (F1).

4. Select Devic (F1).

5. Press the

key to return to the top-level menu.

6. Select Local (F1).

7. Select Bckup (F2).

8. Select DrBU to drop the backup call.

No error messages should appear. Refer to

Appendix C, the Device Health and Status Messages
section, should there be a problem with the DDS Line.

Other Tests

The following lists the tests available on your DSU.

Refer to the Test Branch section of Chapter 4 for further
test information, as well as more detail on how to
configure and operate the DSU. Refer to Appendix A to
determine how best to access each test.

Device Test (Devic)

Local Loopback (LL) – DSU only

DTE Loopback (DTE)

Digital Loopback (DL)

Remote Digital Loopback (RL) – DBM only

Bilateral Loopback

Digital Test (DT) – DBM only

End-to-End Test (EE) – DBM only

Bit Error Rate Test (BERT)

Lamp Test (Lamp)