Model 3616 dsu jumper straps – Paradyne COMSPHERE 3615 User Manual

Page 36

Advertising
background image

COMSPHERE DualFlow Data Service Units

3-4

December 1996

3615-A2-GB20-20

Table 3-2

Model 3616 DSU Jumper Straps

Strap

Designation

State of

Jumper Strap

Function

J12

Left

V.35 Test Mode Indication:

Left — Enables V.35 Test Mode Indication (Pins 1 and 2).
This is the factory default.

Right — Disables V.35 Test Mode Indication (Pins 2 and 3).

J13

Left

EIA-232-D Test Mode Indication:

Left — Enables EIA-232-D Test Mode Indication (Pins 1 and 2).
This is the factory default.

Right — Disables EIA-232-D Test Mode Indication (Pins 2 and 3).

J20

Left

Alarm Monitoring (used with the –48 Vdc Central Office Power Unit):

Left — Disables the – 48 Vdc alarm monitoring function
(Pins 1 and 2).

This is the factory default.

Right — Enables the – 48 Vdc alarm monitoring function
(Pins 2 and 3); the NMS adapter cable is being used for alarm
monitoring.

J21

Right

Alarm Monitoring (used with the –48 Vdc Central Office Power Unit):

Left — Enables control of alarm monitoring via the NMS adapter
cable (Pins 1 and 2); the NMS adapter cable is being used for alarm
monitoring.

Right — Disables control of alarm monitoring via the NMS adapter
cable (Pins 2 and 3); a standard EIA-232 cable or the NMS adapter
cable is being used for the diagnostic channel.

This is the factory

default.