Model 3616 dsu installation and circuit pack lock – Paradyne COMSPHERE 3615 User Manual

Page 38

Advertising
background image

COMSPHERE DualFlow Data Service Units

3-6

December 1996

3615-A2-GB20-20

4. Using a Phillips screwdriver, loosen the screw

holding the circuit pack lock and rotate the lock to
the open position (Figure 3-3). Open the latch.

5. At the front of the carrier, hold the DSU vertically

with the latch on its faceplate in the open position.
Then, insert the circuit card into the top and
bottom circuit card guides for the slot that
contains the rear connector plate.

Slide the DSU into the slot, aligning the circuit
card with the rear connector plate until the
connectors seat firmly into the back of the carrier.
Press the faceplate latch to secure the DSU into
the carrier, rotate the circuit pack lock into the
closed position (Figure 3-3), and tighten the screw.

6. Return to the rear of the carrier and tighten the

rear connector plate screw.

Figure 3-3. Model 3616 DSU Installation and Circuit Pack Lock