Unit Configuration

5-15

3615-A2-GB20-20

December 1996

Table 5-4

(3 of 3)

DBM Port Configuration Options

CCN by EL: Disab
Next Enab Disab Prev

Configuration Change Notification by External Leads. Controls using the general-purpose output leads to set a CCN
event. This configuration option only has an effect if

Ext Leads is set to ExtLd.

Enab

Change in state of a general-purpose lead signals CCN to the NMS.

Disab

General-purpose lead changes do not set a CCN event.

DTR Alarm: Disab
Next Enab Disab Prev

Data Terminal Ready Alarm. Causes the DSU to generate an alarm if DTR is Off for more than 30 seconds. The DCP
displays

DTR Alarm and reports the alarm to the NMS.

Enab

If DTR lead turns Off for 30 seconds, the DSU generates an alarm.

Disab

Regardless how long the DTR lead is Off, no alarm is generated.

Async

Sync: Enab for DiDg, Disab for SyBC and SyBT configurations

Next Enab Disab Prev

Asynchronous-to-Synchronous Conversion. Sets the DBM port for asynchronous or synchronous operation.

Enab

Configures the DBM as asynchronous (asynchronous-to-synchronous conversion takes place).

Disab

Configures the DBM as synchronous.

AsyncBit/Char: 8 for DiDg configuration
Next 6 7 8 9 10 Prev

Asynchronous Bits per Character. Specifies the length of a character, including the parity bit but excluding the start and
stop bits. This configuration option only applies to the Dial Diagnostic (DiDg) configuration.

6 to 10

Selects the asynchronous bits per character. When Stop Bits is set to 2, 10 will not be displayed.

Stop Bits: 1 for DiDg configuration
Next 1 2 Prev

Stop Bits. Specifies the number of stop bits in an asynchronous character. This configuration option only applies to the
Dial Diagnostic (DiDg) configuration.

1 to 2

Selects the number of stop bits to be used. When the AsyncBit/Char configuration option is set to 10, 2
will not be displayed.

Overspeed: 2.3 for DiDg, not applicable for other configurations
Next 1.0 2.3 Prev

Overspeed. Selects the overspeed range of the asynchronous-to-synchronous converter. This configuration option is
only displayed when the Async

Sync configuration option is enabled.

1.0

Selects the basic overspeed range. Basic range provides 1.0 % overspeed in the DTE or router
asynchronous data rate.

2.3

Selects the overspeed percentage for extended range. Extended range provides 2.3% overspeed in the
DTE or router asynchronous data rate.