Dsu status indicators – Paradyne COMSPHERE 3615 User Manual

Page 93

Advertising
background image

COMSPHERE DualFlow Data Service Units

C-2

December 1996

3615-A2-GB20-20

Table C-1

DSU Status Indicators

Label

Color

Description

OK

Green

Health and status indicator: DSU operation is normal. (The DSU has not
detected any of the faults listed under Alrm, below.)

This indicator flashes two times per second if a message from the NMS is
present.

Alrm

Red

Health and status indicator:

There is a fault in the local or remote DSU, DBM, or DDS facility, or there is a
corrupted configuration.

The following alarms at the local or remote DSU cause the Alrm status
indicator on the affected DSU to light:

Configuration Corrupt
Device Fault
Dial Tone Test Failure
DTR Alarm
Facility Alarm
MUX Failure
No Response
Redundant Power Alarm
Streaming Terminal
Subnetwork Alarm
Out-of-Frame Threshold
Out-of-Service

Test

Yellow

Active device (DSU or DBM) is either performing a test or other DSUs or DBMs
are in Test mode.

1

Dial

Yellow

DBM is active

Rapid flashing: Call setup in progress
Slow flashing: Call established but in Standby mode
Steady ON: Backup call established and active

TXD, RXD, RTS,
CTS, DSR, DTR,
LSD

Green

Internal lead states at the DSU/DTE interface

(circuit designations):

Control circuit active

or

Data circuit SPACE(ing).

Front Panel
(Model 3616 only)

Yellow

DSU is currently selected at the SDCP.

(The SDCP addresses one DSU at a

time.)

1

The DSU or DBM is automatically put into Test mode when a remote DSU or DBM is performing a disruptive test (e.g., a
Local Loopback (LL) at the control DSU. A DSU or DBM in Test mode has its DTE interface turned Off).