Troubleshooting – Planar BAT24SI User Manual

Page 19

Advertising
background image

14

Planar Battery System BAT24SI

QUICK LINKS

Contents

Index

Regulatory Compliance

Product Information

Warranty

GETTING STARTED

About the Battery System

Battery Components

Identify Connector Ports

Install Fuses

USING THE BATTERY

Charge Battery

Set Up Power Management

MAINTAINING THE BATTERY

Replace Battery

Troubleshooting

APPENDIXES

Battery Disposal

Specifications

Troubleshooting

Problem

Possible Cause

Possible Solution

The battery system not functioning,
no output power, does not charge
when connected to AC power.

AC power is not connected.

Make sure power cord is connected properly.

Input fuse needs to be replaced.

Replace fuse in the input AC connector.
Replace with UL-recognized fuse 2 A,
250 VAC, fast acting, size 5 mm x 20 mm.

Over-temperature protection is activated.

Contact Planar.

No power supplied to the load.

Output power cord not connected properly.

Make sure that output power cord is

connected correctly.

Power switch is off.

Turn on the power switch on your device.

Output fuse needs to be replaced.

Replace the output power fuse located next
to output power connector. Replace with
UL-recognized fuse 6 A, 125 VDC, fast acting,
size 0.25 in. x 1.25 in., type F.

Batteries not connected correctly.

Check battery connections.

System run time is too short.

Battery not completely charged.

Connect AC power and let battery charge

completely. Charge status is conveyed
through the

Power Meter tab

on the

Power Options Properties dialog Note that
the LED turns green at 80% of total charge
capacity.

Battery capacity is low.

Replace battery.