Installing fence handwheel, Knife gauge assembly (model 60c only), Storing the push blocks – Powermatic 60HH User Manual

Page 12: Electrical connections

Advertising
background image

12

Installing Fence Handwheel

Refer to Figure 12.

Install the handwheel (H) onto the shaft, and
tighten the set screw with a 3mm hex wrench.

Knife Gauge Assembly

(model 60C only)

Refer to Figure 13.

The knife gauge assembly consists of a bar, two
end pieces and two e-clips. Slide the end pieces
onto the ends of the bar as shown, and use a
pliers to push the e-clips into the grooves on the
bar.

Storing the Push Blocks

The two provided push blocks have a magnetic
base – you can attach them to the jointer stand
or any metallic surface, to keep them within
easy reach.

Electrical Connections

Electrical connections must

be made by a qualified electrician in
compliance with all relevant codes. This
machine must be properly grounded to help
prevent electrical shock and possible fatal
injury.

The Jointer is equipped with either a single
phase, 230 volt motor; or a three phase,
230/460 volt motor.

The single phase unit is factory wired for 230
volts. You may either install a UL/CSA listed
plug suitable for 230 volt operation, or “hard-
wire” the jointer directly to a service panel. It is
recommended that the single phase jointer be
connected to a dedicated, minimum 20 amp
circuit with a 20 amp circuit breaker or time
delay fuse. Local codes take precedence over
recommendations.

The three phase motor is pre-wired for 230 volt.
It may be re-connected for 460 volts by
changing the connections as illustrated in the
diagram in the starter box (see “Converting from
230 Volt to 460 Volt”). You may either install a
UL/CSA listed plug suitable for the specific
voltage, or “hard-wire” the jointer directly to a
service panel. It is recommended that the three
phase
jointer, when operated at 230 volts, be
connected to a dedicated, minimum 20 amp
circuit with a 20 amp circuit breaker or time
delay fuse. When operated at 460 volts,
connect the jointer to a dedicated, minimum 15
amp circuit with a 15 amp circuit breaker or time
delay fuse. Local codes take precedence over
recommendations.

Figure 12

Figure 13

(model 60C only)

Advertising
This manual is related to the following products:

60C