Warning, Po d d j – Peerless Industries Peerless-Av Dukane Projector Short Throw Wall Arm UST-WallArm3 User Manual

Page 5

Advertising
background image

5 of 14

ISSUED:07-25-11 SHEET #: 125-9225-1

Using wall plate (

D) as a template, drill four 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach

wall plate (

D) to centers of wood studs using four #14 x 2.5" wood screws (J) shown in figure 1.1.

Fasten wall arm bracket (

C) loosely to wall plate (D) using four M5 x 8 mm pan head black screws (P), and

four #10 black washers (

O).

Installation to Single Wood Stud Wall

1

P

O

D

D

J

DIAMOND INDICATES

TOP OF WALL PLATE

C

fig 1.1

fig 1.2

• Installer must verify that the supporting surface will safely support the combined load of the equipment and all

attached hardware and components.

• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the

screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder

is highly recommended.

• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install-

ers are responsible to provide hardware for other types of mounting situations.

WARNING