Trial run at torque control mode, Operation with cn x5 connected, Wiring diagram parameters input signals status – Panasonic MINAS A3 Series User Manual

Page 10

Advertising
background image

140

Trial run at Torque Control Mode

Operation with CN X5 Connected

1) Connect CN X5.

2) Connect the control signal (COM+/COM–) to the power supply (12 to 24 VDC) .

3) Turn the main power (driver) ON.

4) Check the defaults of the parameters.

5) Connect between SRV-ON (CN X5 pin 29) and COM- (CN X5 pin 41) to make Servo-On active. The motor

will be kept excited.

6) Apply an appropriate DC voltage between Torque command input TRQR (CN X5 pin 14) and GND (CN X5

pin 15) and verify the motor rotating direction (CW/CCW) and then reverse the voltage polarity and then
verify reversed motor rotation. Also check the speed set by Pr56.

7) To change torque Pr5C, direction Pr5D and speed limit Pr56 in response to the command voltage,

modify the following parameter.
Pr56: 4th speed
Pr5C: torque command input gain
Pr5D: torque command input inversion

See page 144 "Parameter setting" in Torgue control mode.

COM+

SRV-ON

SPR/TRQR

GND

ZEROSPD

COM–

7

29

14

15

26

41

DC
12V – 24V

ZEROSPD switch
Close: Run
Open: Stop

One way
operation

For multi direction
(CW and CCW)
operation, use a
bipolar power
source.

DC
10V

Wiring Diagram

Parameters

Input Signals Status

PrNo.

No.

Input signal

Monitor

display

Pr02

Pr04

Pr06

Pr56

Pr5C

Pr5D

0

2

3

5

+ A

Servo-ON

CW overtravel inhibit

CCW overtravel inhibit

Speed zero clamp

2

1

0

Set as

required

Control mode set-up

Overtravel input inhibit

ZEROSPD input selection

4th internal speed

Torque command input gain

Torque command input inversion

Value

Parameter description

• Use the controller to send command pulses.